AW: doubleing the wall at expansion joint #4 (Permalink)
Social Bookmarks:

Water should never enter the gap. The gap must be sealt on the roof with 2 or 3 layers of waterproofung. The gap itself must be closed with some kind of filling (Weicheinlage in German), wich must be fireproof and ontop a PE round cord to compensate the movement forces of the two building parts to the waterproofing layers.
__________________
Florian Illenberger

tektorum.de - Architektur-Diskussionsforum